1. Introduction to top
The APSON 2C Switching Block XMY-2009 HB with Backpropagation
belongs to the class of the special switching blocks for 2-components
lacquers with hardener. Due to its characteristics it improves the quality
and increases the efficiency of the coating process.
This type of switching block is particularly suitable to the
employment in automatic coating systems with often to change chemically
aggressive media, e.g. lacquers, hardeners, solvents, caustic solutions,
a.o. It is applicable both for 2C normal lacquers and 2C metalic
lacquers.
Conventional medium switching blocks for 2-components lacquers are
not optimized and have usually channels for supplying the lacquer
components and at least one channel for exhaust of the lacquer product. In
practice the lacquer product in these channels can harden. This leads to
problems during painting and when rinsing the medium switching blocks.
Clogged medium switching blocks must be exchanged at expensive timely
costs and the medium channels must again be drilled out.
The APSON 2C Switching Block XMY-2009 HB with Backpropagation is
equipped with high-quality dead-space-free APSON valve technology and has
mixing areas with minimum volume within the ranges within which the master
lacquer mixes with the hardener. These mixing areas are optically
examinable and fastly cleanable. Hardenings of the lacquer product cannot
develop during the normal operation. If this should occur nevertheless,
the ready status of the APSON 2C Switching Blocks is restorable in
shortest time.
The APSON 2C Switching Block XMY-2009 HB with Backpropagation has
the following capability caracteristics:
-
Produces high-quality medium mixture by turbulent pre-mixing of
the media already when meeting the media in the mixing area.
-
Does not form air columns because the mixing area has no media
channels.
-
Reaches 100% utilization of material (no hardened medium columns
in channels).
-
Is environmentaly careful due to media recuperation and short
rinsing times.
-
Is cost-saving due to minimized media consumption.
-
Makes possible simple handling when assembling and
maintenance.
-
Has dead-space-free APSON valve technology.
-
Has rinsing- and throughput-optimized media channels.
-
Consists of inoxidable steel, thus corrosion resistant and wear
resistant.
-
Is insensitive to caustic solutions and weak acids.
3. Structure to top
The APSON 2C Switching Block XMY-2009 HB with Backpropagation
consists mainly of:
-
A solid valve block with connection- and
valve-designations.
-
Five APSON valves (see Ordering Data).
-
Tube connectors for the connection of the media.
-
Output cone with output terminal, backpropagation connection and
union nut.
-
Optionally two checkvalves (for pulsation air and
solvent).
-
An attaching bracket.
Legend: a = SL screw nut/mother, b = SL screw connection,
c = Checkvalve, d = Checkvalve, e = Valve, f = Pneumatics connection,
g = 2C switching block, h = Union nut, i = Output cone, j = 2C-lacquer
outlet, k = Feedback, l = Attaching bracket, m = 2 Holes ø7 mm,
(horiz. hole spacing 20 mm)
The APSON 2C Switching Block XMY-2009 HB with Backpropagation is
made of inoxidable steel and is fastened by means of the attaching bracket
to a suitable place.
The media hoses are attached by means of the tube connectors at the
respective marked media connections for master lacquer (SL), hardener (H),
diluant resp. solvent (V/Lo), pulsation air (PL) and feedback (RF). The
union nut at the output cone makes possible fast disassembly for purpose
of maintenance resp. inspection.
The 2C-lacquer product necessary for painting results in the mixing
area of the 2C switching block from simultaneous open valves for master
lacquer and hardener. The 2C-lacquer product then flows through the outlet
A of the 2C switching block and through a Mixer/Homogeniser which can be
connected at the outlet.
Channel lengths: Lv = Lw = Lx = Ly = 0.2 mm; Lz = 1.0 mm
Channel volumes: Vv + Vw + Vx + Vy = 0.2 ml; Vz = 0.01 ml
For changing the lacquer, the master lacquer in the lacquer hose can
be pushed out through the exit (RF) by opening the feedback valve, and so
to be gained back for re-use. Subsequently the lacquer hose for the master
lacquer is to be rinsed, as well as the 2C switching block.
For rinsing the 2C switching block, the valves for master lacquer
(SL) and hardener (H) are to be closed. Subsequently, the valves for the
solvent (V/Lo) and for the pulsation air (PL) are to be opened and closed
periodically and alternating. Thus an air/solvent sequence results as
follows: air-solvent-air-solvent...
5. Technical Data to top
Denomination: |
APSON 2C Switching Block XMY-2009 HB
with Backpropagation |
Media: |
Normal and metalic lacquers, hardener, solvent, caustic solutions,
a.o. |
Media pressure: |
Max. 20 bar |
Valve assembly: |
APSON 2/2-Ways Valves 2009, dead-space-free valve technology |
Material: |
Inoxidable steel |
Seals: |
Viton™, or in accordance with customer's request |
Media entrances: |
For hose D = 8 mm, d = 6 mm (or in accordance with customer's
request) |
Output terminal: |
For hose D = 8 mm, d = 6 mm (or in accordance with customer's
request) |
Dimensions, L x W x H [mm]: |
Without valves: 70 x 70 x 45
With valves:
140 x 140 x 120
|
Mass: |
1.3 kg (with valves) |
6. Ordering Data to top
Denomination |
Quantity |
Part-Nr. |
APSON 2C Switching Block XMY-2009 HB with
Backpropagation (with valves, attaching brackets and SL screw
connections) |
1 |
050-A046 |
APSON 2/2-Ways Valve 2009 (sparepart) |
5 |
060-A013 |
APSON Mixer/Homogeniser |
1 |
200-0270 |
APSON Gasket Kit (sparepart) |
1 |
300-0021 |
APSON Checkvalve for the connection of pulsation air and/or
solvent (option) |
2 |
100-A004 |
Options
-
Other materials or capability characteristics on customer's
request against surcharge.